All in all, the fluke 8010a is a nice bench multimeter. Fluke 179 multimeter circuit diagram fluke 79 series ii multimeter diagram fluke 19 multimeter circuit diagram fluke 8012a fluke y8101 fluke clamp meter diagram fluke 8010a rms dc converter fluke 30 clamp meter diagram fluke 79 iii manual. Level main pcb assembly 865803 display pcb assembly 538306 rms pcb assembly 609120 table 61. The info i have, suggests that the battery option, 01 option should be the same for either 8010 or 8012. Fluke 8010a 8012a digital multimeter instruction manual. The model 8000a is a compact and lightweight digital multimeter dmm. Jun 03, 2019 i bought 6 fluke 8050a benchtop multimeters for parts. To open downloaded files you need acrobat reader or similar pdf reader program. If you purchased an item from a fluke authorized distributor, please contact them directly with. A multimeter is an instrument used to test and measure alternating current ac or direct current dc voltage, resistance, and electric current.
By checking this box, i agree to receive marketing communications and product offers by email from fluke electronics corporation, transacting under fluke industrial, or its partners in accordance with its privacy policy. User manuals, guides and specifications for your fluke 8012a multimeter. Enter a product name or number to find an uptodate fluke product manual. Digital multimeter 8012a equipment fluke, john, mfg. Support requests for items purchased from, or serviced directly by fluke and general metrology questions can be submitted via our online support request form and a fluke. Please select from the following options for a list of local support contacts for all infrared and thermal profiling solutions. Multimeters combine voltmeters, ammeters, and ohmmeters. In the manual it only shows the schematic for the 8010a, so i assume the 8010a, and 8012a use the same schematic and pcb. Category meter usermanualhu if you get stuck in repairing a defective appliance. With the fluke 177 digital multimeter you get truerms voltage and current measurements, 6000count resolution, manual and automatic ranging, and frequency, capacitance, resistance, continuity, and diode measurements. Dc volts, truerms ac volts from 45 hz to 50 khz, dc amps, truerms ac amps, ohms, conductance, and diode test.
I will post back the results when i get the display installed. Fluke 8010a digital multimeter operating instructions. United states and canada latin america asia china india japan. Multimeter fluke 177 truerms digital multimeter fluke. Fluke 8012a multimeter instruction manual pdf viewdownload. The only difference i have seen is the 8010a does amps, and the 8012a does low ohms instead of amps. It lacks a continuity bleeper, though, and unlike modern meters it has no serial interface. The information presented in this manual reflects both instruments except where indicated by a particular model number. It features a 3vz digit display, pushbutton selection of range and function, auto polarity, self locating decimal point, self zeroing to eliminate offset uncertainties, and overload protection for all ranges. Anode ovens paste production for manufacturing green anodes. View and download fluke 8010a instruction manual online.
This site helps you to save the earth from electronic waste. Fluke 8010a operating instructions manual pdf download. The 3466a does not use 5v logic, making it a bit more tricky to connect to a modern microcontroller. This manual contains complete operating and maintenance instructions for the fluke models 8010a and 8012a digital multimeters.
I think a serial interface would be possible, but would require a large number of. View and download fluke 8012a instruction manual online. The fluke 8010a is a 3 12digit portablebench dmm that offers exceptional performance and features. Antique radio forums view topic fluke 8012a info needed. The fluke 8010a digital multimeter is a portable 3. Fluke 8012a multimeter instruction manual pdf view. Fluke s digital multimeters are on more tool belts and finding more problems than any other comparable test tool. Johnnysan the only differences between the 8010a and 8012a are the 8010a has a 10 amp current range and the 8012a has a low ohms range.
Inc everett wa, build 1982, 8 pictures, united states of america, schematics, tubes. Fluke 8010a rms dc converter datasheet, cross reference, circuit and application. View and download fluke 8010a operating instructions manual online. With every meter you get accurate measurements, consistent and. Fluke t6600 part 1, high voltage breakdown testing, with a human hand duration. List of replaceable parts manual status information ref or fluke part revision assembly name option no. Ultimate fluke operation repair service manual 580 pdf manuals on dvd. These changes are documented on a manual supplement which, when applicable, is included with the manual. Control the calibrator remotely from a pc running a terminal emulator program. Fluke 179 multimeter circuit diagram fluke 79 series ii multimeter diagram fluke 19 multimeter circuit diagram fluke 8012a fluke y8101 fluke clamp meter diagram fluke 8010a rms dc converter fluke 30 clamp meter diagram fluke 79 iii manual text. Service manuals, schematics, eproms for electrical technicians. The fluke has an lcd display drive that would complicate things slightly.
Factory rated to 30khz, better than most other fluke portables. Fluke 8010a,8012a instruction manual service manual download. Download instruction manual of fluke 8012a multimeter for free or view it online on. Voltage measurements from 100 v to vdc and 10 mv to 750 vac trms. The fluke 8010a is a portable benchtype digital multimeter with a 3. Fluke 8010a digital multimeter service and user manual. Database contains 2 fluke 8012a manuals available for free online viewing or downloading in pdf. Contacting fluke to order accessories, receive operating assistance, or locate the nearest fluke distributor or service center, call. Full text of fluke 8010a, 8012a instruction internet archive. Feb 03, 2019 in this video i show my first digital meter and compare it with the free meter from harbor freight. The term multimeter is used throughout this manual to indicate both the 8010a and the 8012a. Fluke 8060a service manual y8100 fluke 6010a manual 80j10. If you purchased an item from a fluke authorized distributor, please contact them directly with questions regarding certificates of calibration or other documentation.
Service centers to contact fluke, call one of the following telephone numbers. Having examined the schematics of both the hp 3466a and the fluke 8010a, ive been considering a way to add a serial interface to them. Itll probably replace the hp 3466a on the bench in my home lab. Full text of fluke 8010a, 8012a instruction see other formats 801 0 a801 2 a digital multimeters instruction manual iflukei pn 491944 august 1978 rev 2 1 85 1985, john fluke mfg. Fluke 8000a digital multimeter user manual with schematics.
Fluke 8012a manuals and user guides, multimeter manuals. This video documents the repair and testing of the first meter. Fluke 8010a8012a digital multimeter instruction manual 7. Fluke 8010a,8012a instruction manual service manual.